The problem

A safety argument for a reactor is built from claims, and each claim rests on numbers: a multiplication factor, a temperature, a margin. A number is only as good as the trail behind it. Which calculation produced it? Was it computed, derived from other numbers, or assumed? How uncertain is it? Was the calculation a quick screen or a full one?

In ordinary engineering practice that trail lives in reports, spreadsheets and people's memories, and it frays. Numbers are copied, rounded and retyped. An assumption made early in a project becomes, three documents later, a figure nobody remembers was assumed.

Our system makes the problem sharper. It proposes and checks designs by the thousand, so no person can follow every number by hand, and a language model asked to write about a design will happily produce a plausible figure that no calculation ever made. If AI is going to help with reactor design, its numbers have to be traceable by construction, not by good intentions.

A claim is a sentence with bound values

In our evidence engine, a person writes the sentence of a claim. Each value in it is not typed but filled in from a record in our ledger: the stored result of one physics run, identified by a fingerprint of its contents, so the value in the sentence is always the value in the record.

Every result our design system produces is appended to a hash-chained ledger, so a record cannot be edited after the fact without breaking the chain. A claim's values therefore lead back to one specific run, and that run to the design and the settings it was made with.

Here is the first claim of our demo case, exactly as the engine produced it on 4 Oct 2026. All three values come from one record.

Claim C1 of 8, reactivity control 4 Oct 2026 From our ledger

Cold beginning-of-life multiplication is 1.074985 ± 0.0028;
cold excess is 6,975.5 pcm,
with control holddown residual −24.5 pcm.

A person writes the sentence. Every value in it is filled in from the record, never typed.

Values in claim C1, with status and uncertainty
ValueFigureStatusUncertainty
Multiplication factor, cold, beginning of life 1.074985 Computed ± 0.0028
Cold excess reactivity 6,975.5 pcm Derived None stated
Control holddown residual −24.5 pcm Derived None stated

Computed: from a physics run.Derived: from a model and stated assumptions. pcm (per cent mille) is one hundred-thousandth, the usual unit for small changes in reactivity.

The residual is how far cold excess sits from the planning allowance for what the control system must hold down; negative means inside it. It is not a shutdown margin: that evidence is one of the declared gaps.

Bound to record edcc6cd2…f22c, from a screening run of Monte Carlo reactor physics. Uncertainty is shown where the record states one.

Draft check
Passed
Release
Refused: Rests on screening runs, not full-detail ones
Evidence gaps
6 declared, by safety principle:
  • Reactivity control
  • Heat removal
  • Containment and shielding
  • Fuel integrity
  • Security and safeguards
  • Inherent safety
Claim C1 of the demo case, rendered from the engine's output. Real output for a design from our system; not a finding that the design is safe.

Status travels with the number

Each value keeps the status it was born with. The multiplication factor, 1.074985 ± 0.0028, is computed: it came straight from a Monte Carlo physics run, and the run states its statistical uncertainty. The other two values are derived, and they depend on a modelling assumption, so they carry both labels. They state no uncertainty, and the record shows that plainly rather than inventing one.

Status never improves by being copied. A derived value that rests on an assumption stays marked that way in every claim that uses it, so a reader can see at a glance which parts of an argument are calculation and which are judgement.

Missing evidence is declared

A case has to say what it does not yet show. The demo case holds 8 claims and declares 6 gaps, one for each safety principle it cannot yet support, from heat removal to security and safeguards. The control holddown residual in the claim above, for example, is a screening measure, not a shutdown margin; shutdown margin evidence is one of the declared gaps. A gap written down is useful; a gap left unsaid is a hazard in itself.

Why untraceable numbers are refused

If a value cannot be traced to a record, the engine refuses the claim. It does not warn and carry on. This is deliberately strict. A free-typed number may well be right, but nobody can check it, and the cost of finding it later, after other claims have been built on it, is far higher than the cost of tracing it now. Refusal also closes the easiest way for an AI system to mislead: by producing a confident figure with nothing behind it.

Two checks, and what each one means

A case goes through two checks. The draft check asks whether the case is internally honest: every value bound to a record, every status kept, every gap declared. The release check asks more, including that the evidence rests on full-detail physics runs rather than quick screening runs.

The demo case passes the draft check and is refused release, because its claims rest on screening runs. That refusal is the system working as intended: a fast screen is good enough to steer a search, and not good enough to stand behind in an argument about safety.

Why a pass is not a safety finding

Both checks test the trail, not the physics and not the design. A complete trail can faithfully preserve a wrong answer: a flawed model, a mistaken assumption, a calculation that answers the wrong question. Traceability makes such errors findable; it does not find them.

So a pass means every number can be followed to where it came from, with its status and its gaps in view. Whether the design is safe is a separate question, answered by people who write and review safety cases, and in the end by a regulator. Our engine is built to make their work faster and their questions easier to answer, not to answer for them.

When a result of ours does not hold up, we withdraw it and say so, and the withdrawn entry stays in our development log.

What comes next

Two things. First, evidence cases whose claims rest on full-detail runs, so that release can pass. Second, independent review: we want people who write safety cases to try the approach on a problem of their choosing and tell us what it catches and what it misses. That is one of the three projects on our Work with us list.

Questions or corrections to hello@hexi.industries.